Feel free to roast me if this is idiotic. Thank you!

top 17 comments
sorted by: hot top controversial new old
[-] [email protected] 6 points 1 year ago* (last edited 1 year ago)

There's a lot more we really need to know before saying if that's safe or not. We can only see a small section in your picture.

The first things I would ask are what it's for, how long/often does it run, and is that wiring rated to be outdoors while unprotected?

[-] [email protected] 4 points 1 year ago* (last edited 1 year ago)

Ah good questions! It's powering a security camera that would be constantly running and uses '12 V DC ±25%, Max. 5.32W' according to the specs.

It's this guy for what it's worth:

https://www.defendercameras.ca/products/guard-pro-2k-wifi-plug-in-power-security-camera

It says on the page that "The power supplies are not water-resistant and should not be used outdoors", so I'm not sure if that just means they shouldn't be exposed to water (which they wouldn't be here). Defender also has this installation video in which they specifically say it can be plugged in outside, but isn't recommended only for water concerns (2m 24s):

https://m.youtube.com/watch?v=6rt3H97-g-w

All that to say I think it's inherently safe to be outside and covered, but I just have no idea if making contact with an aluminum soffit is dangerous at all :)

[-] [email protected] 12 points 1 year ago

As long as the whole wire run is that neat, the soffit probably isn't anything to be concerned about, but personally i would run a cable support on the frame and put the wire in that, instead of how you have it here.

Water doesn't just mean submerged. Water comes from humidity, condensation and dew daily. If it's not rated for that then it will likely fail after some time. It's being used in a way it wasn't designed to be, that has an effect on the lifespan of a device. To mitigate that you could put it inside of some type of conduit.

I typed all of this out, and then decided to check your link for better pictures. That camera comes with ethernet waterproof cable shielding. I'm guessing that is exactly enough to go from the camera to the mounting bracket. So no, none of this cable is rated to be outdoors, this is not a safe way to install it. You either need to run conduit or penetrate the wall behind the mounting hardware and feed it through there.

[-] [email protected] 3 points 1 year ago

Damn, this makes a lot of sense. Is there any kind of conduit you would recommend then? I think I've seen that anything PVC is ideal for outdoor cables. Would that also help with the condensation risks?

[-] [email protected] 2 points 1 year ago

No, pvc is not water tight at all. I'd grab some sealtight flexible conduit, nonmetallic would be fine. Just grab some one hole straps and support the conduit every 6-8 feet. It's under your deck and you're a homeowner, not a professional; theres no reason to try and make it straight or neat.

You will need some sort of an enclosure to run the sealtight to. Any outdoor rated junction box should be fine, mount it as close as you can because your going to be using that ethernet watertight protector to go from the junction box to the camera itself. I'd probably just mount the camera to the enclosure cover itself and make it easy.

[-] [email protected] 2 points 1 year ago

My god I have so much to learn. That makes a lot of sense. Thanks so much for all your help. I'll get cracking on this in the coming days you might get a few DMs in the near future haha.

[-] [email protected] 3 points 1 year ago

No worries man, glad to help.

[-] [email protected] 2 points 1 year ago* (last edited 1 year ago)

I was gonna DM you but I figured I might as well keep it here in case it can help someone else :)

It looks like the first few inches of cable coming out of the camera (the segment with the power/ethernet splitter) is outdoor rated. It's just the thin extension cable and power block cable that are meant for indoors it seems.

So what if I bought something like this?

Being sure that it's compatible, I could run this outdoor rated cable all the way to a junction box right beside the outlet, instead of installing conduit the whole way. Is that a crazy idea?

[-] [email protected] 1 points 1 year ago

Yeah, as long as it's rated for outdoors you should be fine. And a little extra tape and heatshrink are always worth it in the long run.

[-] [email protected] 2 points 1 year ago

Amazing. I wish I could pay you but I hope my thanks are enough :)

[-] [email protected] -4 points 1 year ago

Not an electrician but 12V dc is relatively low current.

I don’t think that’s any kind of electrocution/shock hazard (assuming there’s some kind of drip loop where water can’t flow down the plug to a socket)

That being said what about the equipment? Is it expensive enough that a short frying it out would be a huge problem?

[-] [email protected] 6 points 1 year ago

While I understand this may not be useful reply to you … if you used Power Over Ethernet, the cable is low voltage so it wouldn’t matter where you put it (should still be outdoor rated)

[-] [email protected] 1 points 1 year ago

Thanks for this! According to the product page, the default cables are '12 V DC ±25%, Max. 5.32W'. A quick googling tells me PoE can be anywhere from 12-70V. Would I be correct in assuming that this cable is also fairly low-risk? I know it's not outdoor rated however.

[-] [email protected] 2 points 1 year ago

Oh, ok. I can’t speak to electrical code on that, but if it were me, I wouldn’t worry about safety

If it’s not outdoor rated, you need to watch out for UV from sunlight and getting wet. If that keeps it out of the rain and sun, it still might have a shorter life

I personally would go for it, given that cameras are pretty cheap and what we see of the install is easy. I don’t think anyone could put a number on life expectancy so it’s a gamble vs cost of replacing or impact if it dies. I don’t know whether it’s good advice though

[-] [email protected] 1 points 1 year ago

Hey that's fair! I appreciate your thoughts and your honesty :)

[-] [email protected] 1 points 1 year ago

Also sorry for the rotated pic... turn it 90° to the right :)

[-] [email protected] 1 points 6 months ago

For voltage 12V DC - no problem.