It’s bizarre that thermostatic mixers are costly in the US. I can get a new one as cheap as €25 if I shop out the sales, or probably €10 2nd hand.
Tankless water heaters are really lagging as well in the US, and absurdly costly. I’m sure that will get corrected eventually. But in Europe tankless boilers are the norm and used in combination with thermostatic mixers. The lack of tank causes a delay in hot water because it’s less instant than a pre-heated tank. The heating element takes time to fire and reach a high temp. So you are even more tempted to open the hot valve 100% until the hot water comes, which means you have to diligently readjust the valve to avoid scalding.
The luxury fix to that delay is to have a 3rd pipe that cycles the (cold) hot water line to keep it hot in the pipes. This seems quite wasteful and complex so I wouldn’t want to install that.
Even a couple of dollars more for a contractor is a lot when a thermostatic valve doesn't add any value.
You can get inexpensive tankless water heaters.
You want to open the hot valve 100% until the hot water comes because it conserves water. You want to clear out the hot water line as fast as possible. Turning it to 70% just takes longer to heat up and you're just dumping cold water out for no reason.
This is precisely what a thermostatic valve gives you. I don’t think you know how a thermostatic valve works. If the thermostat on the mixer bar is set at 38°C and you turn on the pressure control when the water in the hot line is cold, a thermostatic valve opens the hot 100% immediately and when the hot water arrives at the fixture it automatically adjusts. What you say about starting 70% open is exactly the problem you have when /not/ using a thermostatic valve, like the pressure balance valves that are common in the US.
(edit) also consider how tankless heaters have a minimum threshold for turning on. If you open the hot valve just a little, the heater will not be triggered. It must be open enough to trip the flow switch. It can be tricky to open the valve just enough to trigger the heat. A thermostatic mixer valve solves that.
I don’t think you saw the pic I posted of the cheap thermostatic mixer bar. Those can be installed by anyone because they are external. You just turn two union nuts until hand-tight then give ¾ turn extra with a wrench.