this post was submitted on 21 Dec 2023
606 points (98.2% liked)

memes

10147 readers
1937 users here now

Community rules

1. Be civilNo trolling, bigotry or other insulting / annoying behaviour

2. No politicsThis is non-politics community. For political memes please go to [email protected]

3. No recent repostsCheck for reposts when posting a meme, you can only repost after 1 month

4. No botsNo bots without the express approval of the mods or the admins

5. No Spam/AdsNo advertisements or spam. This is an instance rule and the only way to live.

Sister communities

founded 1 year ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[โ€“] [email protected] 39 points 10 months ago* (last edited 10 months ago) (1 children)

The strands' fuses probably wouldn't see that current though. These are connected in parallel.

The first plug has all the current passing through it, but I'm not sure that would reach a fuse if it's down-circuit protecting the lights.

[โ€“] [email protected] 23 points 10 months ago

Also, trying to tie a breaker in the closed (on) position like that won't stop it from tripping. It'll just make it more difficult to reset.

When tripped, the internal electrical part detaches from the lever mechanism and switches to the off position. The lever will then normally be ether free floating or spring to the middle (between on and off) until it is moved to the off position. Moving it to the off position will reattach the lever mechanism to the electrical part, which then allows it to be turned back on.