this post was submitted on 07 Jan 2025
168 points (96.2% liked)

Hardware

833 readers
245 users here now

All things related to technology hardware, with a focus on computing hardware.


Rules (Click to Expand):

  1. Follow the Lemmy.world Rules - https://mastodon.world/about

  2. Be kind. No bullying, harassment, racism, sexism etc. against other users.

  3. No Spam, illegal content, or NSFW content.

  4. Please stay on topic, adjacent topics (e.g. software) are fine if they are strongly relevant to technology hardware. Another example would be business news for hardware-focused companies.

  5. Please try and post original sources when possible (as opposed to summaries).

  6. If posting an archived version of the article, please include a URL link to the original article in the body of the post.


Some other hardware communities across Lemmy:

Icon by "icon lauk" under CC BY 3.0

founded 2 years ago
MODERATORS
 

The first salvo of RTX 50 series GPU will arrive in January, with pricing starting at $549 for the RTX 5070 and topping out at an eye-watering $1,999 for the flagship RTX 5090. In between those are the $749 RTX 5070 Ti and $999 RTX 5080. Laptop variants of the desktop GPUs will follow in March, with pricing there starting at $1,299 for 5070-equipped PCs.

you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 1 points 14 hours ago (1 children)

The NEC limits CONTINUOUS loads to 80%, not intermittent loads. Continuous loads are things like heaters, AC units, etc. Things plugged into the wall are generally not considered continuous loads, so your breakers in a residential home are usually not derated, and receptacles never are from what I've seen. (Although it could be argued that a gaming computer would be a continuous load, as it runs 3+ hours for many people, but there's still no electrician that would treat it that way, probably ever, unless it was some kind of commercial space that rented gaming seats or something. Either way it would be planned in advance)

The rule that you're describing is for the initial planning of the circuit. It's for the rating of your wires and overcurrent protections, which is done at the time of installation, based on the expected continuous and intermittent loads. For residential planning nobody treats a standard branch circuit for wall receptacles as somewhere you'd derate, so your 15A circuit is a 15A circuit, you don't need to do any more math on it and derate it further.

[–] [email protected] 1 points 13 hours ago (1 children)

You could make the argument that people with 5090s do run their PCs longer than 3 hours since those folk are more prone to longer bouts of gaming to feel like they're returning on their expensive investment. And as the capabilities of our PCs become more and more robust, it will likely mean that people will more and more need to consider whether the circuit they're plugging into will take the load they're giving it.

Doesn't hurt to plan for the future regarding building wiring, since most tech folk do so regarding their PC builds.

But, up on further inspection... I may be inclined to agree with you. See this thread from licensed and qualified professionals in the space.

It seems that homeowners are given a special class of immunity when it comes to manifesting hazards associated with their use of electricity. Whether or not that immunity should be granted, given that improper use of electrical equipment in a household can lead to fires and cause undue harm to the community at large, I think is up for debate.

[–] [email protected] 1 points 1 hour ago

You could make the argument that people with 5090s do run their PCs longer than 3 hours since those folk are more prone to longer bouts of gaming

I think this is what I said also, yes

Doesn't hurt to plan for the future regarding building wiring, since most tech folk do so regarding their PC builds.

I completely agree. IMO 15A convenience circuits (normal wall circuits in residential homes) are out of date and shouldn't be used any longer. 20A should be the minimum, but that extra copper is expensive, so it's a balance that has to be weighed at construction.

seems that homeowners are given a special class of immunity when it comes to manifesting hazards associated with their use of electricity

No, I don't think that's what this is. The fact is that the NEC is for building design, not for building use. The whole reason that there's a breaker installed that has to be matched to the correct gauge wires and the correct outlets, or whatever, is so that when the occupant does something dumb it trips long before you get enough heat to start a fire.

The NEC is not for the occupant, it's for the architects, general contractors, and electricians. Unless you're doing construction in your house you don't need to worry about it at all.

Use your breakers to their capacity, but understand that the closer you get to their rating the more likely you'll pop a breaker, or worst case start a fire if your stuff wasn't installed well.

But you don't have to derate your own stuff per NEC requirements, that's not how it works.