this post was submitted on 03 Jul 2024
9 points (84.6% liked)
Ask Electronics
3325 readers
1 users here now
For questions about component-level electronic circuits, tools and equipment.
Rules
1: Be nice.
2: Be on-topic (eg: Electronic, not electrical).
3: No commercial stuff, buying, selling or valuations.
4: Be safe.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
Measured voltage is completely dependent on what is used as a reference. If you were to measure the voltage of a power supply set to +30V with a voltmeter whose leads were backwards (ie positive on the voltmeter connected to negative on the power supply, and negative connected to positive), then you would measure -30V. All this is to say that if you connect your 30V supply "backwards", you will have -30V. Now, there may be some circuitry in the power supply that only allows current in one direction, and it could be that it's able to source a different amount of current than it's able to sink, so be sure to check its manual.
I'd advise caution against arbitrary decisions with electronics — both for your own safety and the safety of the equipment.
It would be weird for say, a 12V-2A PSU to not be able to source and sink 2A. The current direction didn't change from the PSU perspective, only from the load. If you have multi-rail power supply, then yeah it may have different source-sink capabilities for different rail